<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Habilitations électriques - ASP Formation</title>
	<atom:link href="https://www.aspformation.com/habilitations-electriques/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.aspformation.com/habilitations-electriques/</link>
	<description></description>
	<lastBuildDate>Wed, 03 Jul 2024 10:49:35 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.aspformation.com/wp-content/uploads/2024/03/Favicon-150x150.png</url>
	<title>Habilitations électriques - ASP Formation</title>
	<link>https://www.aspformation.com/habilitations-electriques/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Non électricien : Exécutant ou Chargé de chantier (B0- H0- H0V)</title>
		<link>https://www.aspformation.com/non-electricien-executant-ou-charge-de-chantier-b0-h0-h0v/</link>
		
		<dc:creator><![CDATA[Mathieu]]></dc:creator>
		<pubDate>Thu, 12 Sep 2019 15:12:00 +0000</pubDate>
				<category><![CDATA[Habilitations électriques]]></category>
		<guid isPermaLink="false">http://www.ere-m.com/?p=2286</guid>

					<description><![CDATA[<p>A la fin de la formation, le stagiaire doit être capable de connaître les dangers de l’électricité et d’analyser le risque électrique, d’intégrer la prévention dans l’organisation du travail, de mettre en œuvre les mesures de prévention et les instructions de l’employeur, et de connaître la conduite à tenir en cas d’accident ou d’incendie d’origine électrique.</p>
<p>L’article <a href="https://www.aspformation.com/non-electricien-executant-ou-charge-de-chantier-b0-h0-h0v/">Non électricien : Exécutant ou Chargé de chantier (B0- H0- H0V)</a> est apparu en premier sur <a href="https://www.aspformation.com">ASP Formation</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="2286" class="elementor elementor-2286" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-c839cb5 e-flex e-con-boxed e-con e-parent" data-id="c839cb5" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-4522f2e elementor-tabs-view-horizontal elementor-widget elementor-widget-tabs" data-id="4522f2e" data-element_type="widget" data-e-type="widget" data-widget_type="tabs.default">
				<div class="elementor-widget-container">
							<div class="elementor-tabs">
			<div class="elementor-tabs-wrapper" role="tablist" >
									<div id="elementor-tab-title-7241" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="true" data-tab="1" role="tab" tabindex="0" aria-controls="elementor-tab-content-7241" aria-expanded="false">Public visé</div>
									<div id="elementor-tab-title-7242" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="2" role="tab" tabindex="-1" aria-controls="elementor-tab-content-7242" aria-expanded="false">Moyens pédagogiques</div>
									<div id="elementor-tab-title-7243" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="3" role="tab" tabindex="-1" aria-controls="elementor-tab-content-7243" aria-expanded="false">Détails</div>
									<div id="elementor-tab-title-7244" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="4" role="tab" tabindex="-1" aria-controls="elementor-tab-content-7244" aria-expanded="false">Indicateurs de résultats</div>
							</div>
			<div class="elementor-tabs-content-wrapper" role="tablist" aria-orientation="vertical">
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="true" data-tab="1" role="tab" tabindex="0" aria-controls="elementor-tab-content-7241" aria-expanded="false">Public visé</div>
					<div id="elementor-tab-content-7241" class="elementor-tab-content elementor-clearfix" data-tab="1" role="tabpanel" aria-labelledby="elementor-tab-title-7241" tabindex="0" hidden="false"><p><span style="text-align: var(--text-align); font-size: 1em;"><span style="font-weight: bold;">E</span></span><span style="font-weight: bolder; text-align: var(--text-align); font-size: 1em;">xécutant (B0, H0, H0V)&nbsp;</span><span style="text-align: var(--text-align); font-size: 1em;">: Personne assurant des opérations sous la conduite d’un chargé de travaux, d’un chargé d’intervention générale, d’un chargé d’opérations spécifiques ou d’un chargé de chantier, soit sur des ouvrages ou des installations électriques, soit dans leur environnement.</span></p>
<p><span style="font-weight: bolder;">Chargé de chantier (B0, H0, H0V)</span>&nbsp;: Personne chargée d’assurer la<br>direction des travaux non électriques soit sur des ouvrages ou des<br>installations électriques, soit dans leur environnement. Elle assure la<br>surveillance de son personnel et participe à la mise en application des<br>procédures de préparation, d’accès, de suivi et de contrôle.</p>
<p><span style="font-weight: bolder;">Accessibilité</span> : Cette formation est accessible aux personnes en situation de handicap sous certaines conditions (nous consulter).</p>
<p><span style="font-weight: bolder;">Prérequis&nbsp;</span>Aucun en électricité. Etre capable de comprendre les instructions de sécurité.</p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="2" role="tab" tabindex="-1" aria-controls="elementor-tab-content-7242" aria-expanded="false">Moyens pédagogiques</div>
					<div id="elementor-tab-content-7242" class="elementor-tab-content elementor-clearfix" data-tab="2" role="tabpanel" aria-labelledby="elementor-tab-title-7242" tabindex="0" hidden="hidden"><p>Formateurs en prévention des risques professionnels, Electriciens de formation<br />Supports d’animation pédagogique standardisés, utilisés en vidéo-projection.<span style="font-weight: bolder;"><br /></span></p>
<p><span style="font-weight: bolder;">Méthode pédagogique</span> :Les enseignements théoriques représentent 75 % du temps de formation pratique : En fonction de l&rsquo;environnement de travail du salarié.</p>
<p><span style="font-weight: bolder; text-align: var(--text-align); font-size: 1em;">Type d’action</span><span style="text-align: var(--text-align); font-size: 1em;">.Formation à la sécurité dépendant de </span>l’article L4141-4 du code du travail Formation en présence physique uniquement (pas de FOAD)Formation en intra-entreprise ou en centre de formation spécialisé.</p>
<p><strong>Installations en centre de formation</strong> : salle de cours, tables, chaises, mur clair pour la<br />projection, tableau papier ou effaçable. En cas de formation intra-entreprise,<br />des installations équivalentes doivent être mises à disposition par l’employeur<br />des stagiaires.</p>
<p><strong>Moyens techniques</strong><br /><strong>Attention :</strong> Lors d’une formation intra-entreprise, s’il est impossible d’organiser la formation pratique dans des conditions représentatives d’un chantier électrique réel, celle-ci pourra être organisée dans un chantier-école.<br />Les appareils utilisés en formation et les équipements de protection individuelle (EPI) doivent être conformes à la réglementation et entretenus. La formation ne pourra avoir lieu si ces obligations réglementaires ne sont pas respectées.</p>
<p><strong>Equipements à mettre à disposition par le client (formation intra) :</strong><br />&#8211; Local électrique<br />&#8211; Armoire à l’intérieur du local contenant des pièces nues sous tension en basse tension<br />&#8211; Equipements de protection individuelle (H0V). Chaque stagiaire doit être équipé de ses EPI personnels</p>
<p><strong>Moyens d’évaluation : </strong>Le formateur évalue les acquis du stagiaire (savoirs et savoir-faire) dans les conditions définies par la NF C 18-510, au moyen d’une fiche standardisée correspondant à une procédure intégrée au système qualité de l’organisme. Une attestation de fin de formation est remise au stagiaire à l’issue de la formation, précisant si les objectifs sont atteints ou non, ou en cours d’acquisition.</p>
<p><strong>Evaluations et bilan de la formation</strong></p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="3" role="tab" tabindex="-1" aria-controls="elementor-tab-content-7243" aria-expanded="false">Détails</div>
					<div id="elementor-tab-content-7243" class="elementor-tab-content elementor-clearfix" data-tab="3" role="tabpanel" aria-labelledby="elementor-tab-title-7243" tabindex="0" hidden="hidden"><p><span style="font-weight: bolder;">Codes de formation</span><br /><span style="font-weight: bolder;">Formacode :</span> 24049 – Habilitation électrique NSF : 2553 – Electricité, électronique (non compris automatismes, productique) Textes officiels se rapportant à l’action de formation<br /><span style="font-weight: bolder;">Formation certifiante correspondant au Répertoire Spécifique sous les références RS 1126-1626-1657</span><br /><span style="font-weight: bolder;">Prévention </span>: Articles L4111-1 à L4154-4 du code du travail. Risque électrique : Articles R4544-1 à R4544-10 du code du travail  Opérations électriques : Norme NF C 18-510<br />Formation à la sécurité : Articles L4141-2, R4141-3 et R4141-13 du code du travail</p>
<p><span style="font-weight: bolder;">Durée : </span>7 heures (1 jour)</p>
<p><span style="font-weight: bolder;">Périodicité :  </span>Recommandée tous les 3 ans</p>
<p><span style="font-weight: bolder;">Nombre de participants par groupe</span> : 10 personnes maximum</p>
<p><span style="font-weight: bolder;">Moyens d’encadrement : </span>Organisme de formation déclaré à la DIRECCTE</p>
<p><strong>Programme détaillé de la formation</strong><br /><strong>Module « Tronc commun » :</strong><br />Distinction des grandeurs électriques, telles que courant alternatif et continu, intensité, tension, résistance, puissance…<br />Effets du courant électrique sur le corps humain (mécanismes d’électrisation, d’électrocution, de brûlures…)<br />Nom et limites des différents domaines de tension, reconnaissance de l’appartenance des matériels à leur domaine de tension Identification des zones d’environnement et de leurs limites<br />Principe de l’habilitation et définition des symboles d’habilitation (lecture et exploitation du contenu d’un titre d’habilitation)<br />Prescriptions associées aux zones de travail<br />Reconnaissance des zones de travail ainsi que les signalisations associées (équipements de protection collective et leur fonction)<br />Risques liés à l’utilisation et à la manipulation des matériels et outillages utilisés dans l’environnement<br />Conduite à tenir en cas d’accident corporel<br />Procédures, consignes et conduite à tenir en cas d’incendie dans un environnement électrique</p>
<p><strong>Module « B0 H0 H0V – Exécutants de travaux d’ordre non électrique » :</strong><br />Acteurs concernés par les travaux<br />Limites de l’habilitation chiffre « 0 » :<br />&#8211; Autorisations et interdictions<br />&#8211; Définition des zones de travail qui ont été définies<br />&#8211; Application des prescriptions<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée</p>
<p><strong>Module « B0 H0 H0V – Chargé de chantier non électrique » :</strong><br />Documents et acteurs concernés par les travaux (utilisation des documents correspondant à son niveau d’habilitation et à sa fonction)<br />Limites de l’habilitation chiffre « 0 » :<br />&#8211; Autorisations et interdictions<br />&#8211; Définition et mise en place des zones de travail<br />&#8211; Application des instructions de sécurité<br />&#8211; Surveillance d’un chantier au regard du risque électrique<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée</p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="4" role="tab" tabindex="-1" aria-controls="elementor-tab-content-7244" aria-expanded="false">Indicateurs de résultats</div>
					<div id="elementor-tab-content-7244" class="elementor-tab-content elementor-clearfix" data-tab="4" role="tabpanel" aria-labelledby="elementor-tab-title-7244" tabindex="0" hidden="hidden"><div align="center">
<p>Taux de réussite : 100 %</p>
<img decoding="async" class="alignnone size-full wp-image-5904" src="/wp-content/uploads/2024/07/tx_100.png" alt="" width="176" height="141" /></div>
<p>&nbsp;</p>
<div align="center">
<p>La formation est-elle en adéquation avec vos attentes et vos besoins ? 90 %</p>
<img decoding="async" class="aligncenter size-full wp-image-5892" src="/wp-content/uploads/2024/07/ab_90.png" alt="" width="193" height="153" /></div>
<p style="font-size:0.7em">Résultats mis à jour le 25 juin 2024.</p></div>
							</div>
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-8831c72 elementor-widget elementor-widget-text-editor" data-id="8831c72" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p></p>
<p class="wp-block-paragraph"></p>
<p></p>
<p class="wp-block-paragraph"><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);"><u>Délais de réalisation et tarif :</u></span></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);">Inter : selon le <a href="/calendrier/">calendrier</a> semestriel.</span></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);">Intra</span><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align); font-weight: var( --e-global-typography-text-font-weight );"> : devis envoyé sous 4 heures et planification de la session sous 24 heures selon nos disponibilités.</span></p>
<p></p>								</div>
				</div>
				<div class="elementor-element elementor-element-570976f elementor-widget elementor-widget-post-info" data-id="570976f" data-element_type="widget" data-e-type="widget" data-widget_type="post-info.default">
				<div class="elementor-widget-container">
							<ul class="elementor-inline-items elementor-icon-list-items elementor-post-info">
								<li class="elementor-icon-list-item elementor-repeater-item-8a6b18c elementor-inline-item">
													<span class="elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-custom">
										Programme mis à jour le 3 juillet 2024					</span>
								</li>
				</ul>
						</div>
				</div>
					</div>
				</div>
				</div>
		<p>L’article <a href="https://www.aspformation.com/non-electricien-executant-ou-charge-de-chantier-b0-h0-h0v/">Non électricien : Exécutant ou Chargé de chantier (B0- H0- H0V)</a> est apparu en premier sur <a href="https://www.aspformation.com">ASP Formation</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electricien HAUTE Tension : H1- H1V- H2- H2V- HC- Essai – HE Manœuvre- Mesurage- Vérification)</title>
		<link>https://www.aspformation.com/electricien-haute-tension-h1-h1v-h2-h2v-hc-essai-he-manoeuvre-mesurage-verification/</link>
		
		<dc:creator><![CDATA[Mathieu]]></dc:creator>
		<pubDate>Thu, 12 Sep 2019 15:08:44 +0000</pubDate>
				<category><![CDATA[Habilitations électriques]]></category>
		<guid isPermaLink="false">http://www.ere-m.com/?p=2262</guid>

					<description><![CDATA[<p>A la fin de la formation, le stagiaire doit être capable de connaître les dangers de l’électricité et d’analyser le risque électrique, d’intégrer la prévention dans l’organisation du travail, de mettre en œuvre les mesures de prévention et les instructions de l’employeur, et de connaître la conduite à tenir en cas d’accident ou d’incendie d’origine électrique.</p>
<p>L’article <a href="https://www.aspformation.com/electricien-haute-tension-h1-h1v-h2-h2v-hc-essai-he-manoeuvre-mesurage-verification/">Electricien HAUTE Tension : H1- H1V- H2- H2V- HC- Essai – HE Manœuvre- Mesurage- Vérification)</a> est apparu en premier sur <a href="https://www.aspformation.com">ASP Formation</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="2262" class="elementor elementor-2262" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-4738998b e-flex e-con-boxed e-con e-parent" data-id="4738998b" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-1b74cd1 elementor-tabs-view-horizontal elementor-widget elementor-widget-tabs" data-id="1b74cd1" data-element_type="widget" data-e-type="widget" data-widget_type="tabs.default">
				<div class="elementor-widget-container">
							<div class="elementor-tabs">
			<div class="elementor-tabs-wrapper" role="tablist" >
									<div id="elementor-tab-title-2871" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="true" data-tab="1" role="tab" tabindex="0" aria-controls="elementor-tab-content-2871" aria-expanded="false">Public visé</div>
									<div id="elementor-tab-title-2872" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="2" role="tab" tabindex="-1" aria-controls="elementor-tab-content-2872" aria-expanded="false">Moyens pédagogiques</div>
									<div id="elementor-tab-title-2873" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="3" role="tab" tabindex="-1" aria-controls="elementor-tab-content-2873" aria-expanded="false">Détails</div>
									<div id="elementor-tab-title-2874" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="4" role="tab" tabindex="-1" aria-controls="elementor-tab-content-2874" aria-expanded="false">Indicateurs de résultats</div>
							</div>
			<div class="elementor-tabs-content-wrapper" role="tablist" aria-orientation="vertical">
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="true" data-tab="1" role="tab" tabindex="0" aria-controls="elementor-tab-content-2871" aria-expanded="false">Public visé</div>
					<div id="elementor-tab-content-2871" class="elementor-tab-content elementor-clearfix" data-tab="1" role="tabpanel" aria-labelledby="elementor-tab-title-2871" tabindex="0" hidden="false"><p style="color: #7a7a7a;"><span style="font-weight: bolder; color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">Exécutant (opérations électriques H1, H1V) :</span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;"> Personne assurant l’exécution d’opérations électriques sous la conduite d’un chargé de travaux, d’un chargé d’intervention générale  ou d’un chargé d’opérations spécifiques.</span></p>
<p style="color: #7a7a7a;"><span style="font-weight: bolder;">Chargé de travaux (H2, H2V, H2V Essai) :</span> Personne assurant la direction effective des travaux électriques ou non, qui doit prendre les mesures nécessaires pour assurer sa sécurité et celle du personnel placé sous sa responsabilité et son autorité.</p>
<p style="color: #7a7a7a;"><span style="font-weight: bolder;">Chargé de consignation (HC) :</span> Personne chargée d’assurer des consignations électriques en haute tension (coupure de courant et garantie qu’il ne peut être remis accidentellement).</p>
<p style="color: #7a7a7a;"><span style="font-weight: bolder;">Chargé d’opérations spécifiques (HE Manœuvre)</span> : Personne chargée de diriger ou d’effectuer des manoeuvres sur des installations électriques (changement de la configuration électrique d’un ouvrage, d’une installation ou de l’alimentation électrique d’un matériel).</p>
<p style="color: #7a7a7a;"><span style="font-weight: bolder;">Chargé d’opérations spécifiques (HE Mesurage)</span> : Personne chargée de diriger ou d’effectuer des mesurages (opérations destinées à mesurer des grandeurs électriques ou des grandeurs physiques) sur des installations électriques.</p>
<p style="color: #7a7a7a;"><span style="font-weight: bolder;">Chargé d’opérations spécifiques (HE Vérification)</span> : Personne chargée de diriger ou d’effectuer des vérifications (opérations destinées à s’assurer qu’un ouvrage ou une installation est conforme à un référentiel) sur des installations<br />électriques.</p>
<p style="color: #7a7a7a;"><span style="font-weight: bolder;">Accessibilité</span> Cette formation est accessible aux personnes en situation de handicap sous certaines conditions (nous consulter)</p>
<p style="box-sizing: border-box; margin-block: 0px 0.9rem; color: #7a7a7a; font-family: Poppins, sans-serif; font-size: 16px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: #ffffff; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;"><strong style="box-sizing: border-box; font-weight: bolder;">Prérequis </strong>Aptitude médicale. Etre qualifié en électricité pour les opérations visées par ce programme.  Etre capable de comprendre les instructions de sécurité</p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="2" role="tab" tabindex="-1" aria-controls="elementor-tab-content-2872" aria-expanded="false">Moyens pédagogiques</div>
					<div id="elementor-tab-content-2872" class="elementor-tab-content elementor-clearfix" data-tab="2" role="tabpanel" aria-labelledby="elementor-tab-title-2872" tabindex="0" hidden="hidden"><p>Formateurs en prévention des risques professionnels, Electriciens de formation. Supports d’animation pédagogique standardisés, utilisés en vidéo-projection.</p>
<p><span style="font-weight: bolder;">Méthode pédagogique</span> Les enseignements pratiques et les mises en situations d’évaluation des stagiaires représentent 50 % du temps de formation.</p>
<p><span style="font-weight: bolder; color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">Type d’action</span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">. Formation à la sécurité dépendant </span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">de l’article L4141-4 du code du travail Formation en présence physique </span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">uniquement (pas de FOAD)Formation en intra-entreprise ou en centre de formation </span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">spécialisé.</span></p>
<p><span style="font-weight: bolder; color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">Installations en centre de formation</span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;"> : salle de cours, tables, chaises, mur clair pour la </span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">projection, tableau papier ou effaçable. En cas de formation intra-entreprise, </span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">des installations équivalentes doivent être mises à disposition par l’employeur </span><span style="color: var( --e-global-color-text ); text-align: var(--text-align); font-size: 1em;">des stagiaires.</span></p>
<p><span style="font-weight: bolder; color: var( --e-global-color-text ); font-size: 1em;">Moyens techniques</span></p>
<p><span style="font-weight: bolder;">Attention :</span> Lors d’une formation intra-entreprise, s’il est impossible d’organiser la formation pratique dans des conditions représentatives d’un chantier électrique réel, celle-ci pourra être organisée dans un chantier-école.Les appareils utilisés en formation et les équipements de protection individuelle (EPI) doivent être conformes à la réglementation et entretenus. La formation ne pourra avoir lieu si ces obligations réglementaires ne sont pas respectées.</p>
<p><span style="font-weight: bolder;">Equipements à mettre à disposition par le client (formation intra) :</span><br />&#8211; Local électrique<br />&#8211; Armoire à l’intérieur du local contenant des pièces nues sous tension en basse tension<br />&#8211; EPI et équipements de protection (obstacle, nappe, tapis, tabouret, balisage…)<br />&#8211; Outillage et matériels électroportatifs (dont VAT)<br />&#8211; Equipements à mettre hors service (moteur, machine…) pour les opérations de consignation<br />&#8211; Equipements permettant un dépannage et une connexion (pour les interventions)</p>
<p><span style="font-weight: bolder;">Moyens d’évaluation</span> Le formateur évalue les acquis du stagiaire (savoirs et savoir-faire) dans les conditions définies par la NF C 18-510, au moyen d’une fiche standardisée correspondant à une procédure intégrée au système qualité de l’organisme. Une attestation de fin de formation est remise au stagiaire à l’issue de la formation, précisant si les objectifs sont atteints ou non, ou en cours d’acquisition</p>
<p><span style="font-weight: bolder;">Evaluations et bilan de la formation</span></p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="3" role="tab" tabindex="-1" aria-controls="elementor-tab-content-2873" aria-expanded="false">Détails</div>
					<div id="elementor-tab-content-2873" class="elementor-tab-content elementor-clearfix" data-tab="3" role="tabpanel" aria-labelledby="elementor-tab-title-2873" tabindex="0" hidden="hidden"><p><span style="font-weight: bolder;">Codes de formation</span><br /><span style="font-weight: bolder;">Formacode :</span> 24049 – Habilitation électrique NSF : 2553 – Electricité, électronique (non compris automatismes, productique) Textes officiels se rapportant à l’action de formation<br /><span style="font-weight: bolder;">Formation certifiante correspondant au Répertoire Spécifique sous les références RS 1624-1647-1670-1671-1674-1675</span></p>
<p><span style="font-weight: bolder;">Prévention </span>: Articles L4111-1 à L4154-4 du code du travail. Risque électrique : Articles R4544-1 à R4544-10 du code du travail  Opérations électriques : Norme NF C 18-510<br />Formation à la sécurité : Articles L4141-2, R4141-3 et R4141-13 du code du travail</p>
<p><span style="font-weight: bolder;">Durée : </span>de 7 à 14 heures (2 jours)</p>
<p><span style="font-weight: bolder;">Périodicité :  </span>Recommandée tous les 3 ans</p>
<p><span style="font-weight: bolder;">Nombre de participants par groupe</span> : 10 personnes maximum</p>
<p><span style="font-weight: bolder;">Moyens d’encadrement : </span>Organisme de formation déclaré à la DIRECCTE</p>
<p><span style="font-weight: bolder;">Programme détaillé de la formation</span><br /><span style="font-weight: bolder;">Module « Tronc commun » :</span></p>
<p>Distinction des grandeurs électriques, telles que courant alternatif et continu, intensité, tension, résistance, puissance…<br />Effets du courant électrique sur le corps humain (mécanismes d’électrisation, d’électrocution, de brûlures…)<br />Nom et limites des différents domaines de tension, reconnaissance de l’appartenance des matériels à leur domaine de tension<br />Identification des zones d’environnement et de leurs limites<br />Principe de l’habilitation et définition des symboles d’habilitation (lecture et exploitation du contenu d’un titre d’habilititation)<br />Prescriptions associées aux zones de travail et rôle de chacun des acteurs<br />Principes généraux de prévention à appliquer au cours d’une opération électrique<br />Séquences de la mise en sécurité d’un circuit (consignation, mise hors tension, mise hors de portée) et déroulement des opérations de vérification d’absence de tension<br />Equipements de protection collective et leurs fonctions<br />Equipements de protection individuelle et leurs limites d’utilisation<br />Reconnaissance des zones de travail ainsi que les signalisations associées (équipements de protection collective et leur fonction)<br />Risques liés à l’utilisation et à la manipulation des matériels et outillages utilisés dans l’environnement<br />Conduite à tenir en cas d’accident corporel<br />Procédures, consignes et conduite à tenir en cas d’incendie dans un environnement électrique</p>
<p><span style="font-weight: bolder;">Module « Technique HTB » :</span><br />Identification de la structure et du principe de fonctionnement des ouvrages ou des installations électriques (ligne et poste)<br />Fonctions des matériels électriques des postes (commandes, séparations, protections)<br />Principes et risques liés à l’induction et au couplage capacitif. Mise en œuvre des principes d’équipe potentialité<br />Différenciation des types de postes<br />Principes et manoeuvre de verrouillage et inter-verrouillage pour les matériels concernés<br />Identification, vérification et utilisation des équipements de protection collective<br />Identification, vérification et utilisation des équipements de protection individuelle appropriés</p>
<p><span style="font-weight: bolder;">Module « H1 H1V H2 H2V H2V Essai – Exécutant et Chargé de travaux hors tension en haute tension » :</span><br />Travaux hors tension avec ou sans présence de pièces nues sous tension<br />Rôles du chargé de consignation et du chargé d’exploitation électrique :<br />&#8211; Respect des instruction données par le chargé de travaux (exécutant)<br />&#8211; Identification du chargé d’exploitation et échange des informations nécessaires (chargé de travaux)<br />&#8211; Respect des instructions données par le chargé d’exploitation électrique ou par le chargé de consignation (chargé de travaux)<br />&#8211; Compte-rendu de son activité<br />Identification des différents niveaux d’habilitation (et leurs limites) susceptibles d’être rencontrés dans le cadre des travaux hors tension avec ou sans présence de pièces nues sous tension<br />Prescriptions d’exécution des travaux :<br />&#8211; Organisation, délimitation et signalement des zones de travail<br />&#8211; Elimination du risque de présence de tension dans la zone de voisinage renforcé BT<br />&#8211; Respect des zones de travail<br />Rédaction et vérification des documents applicables dans le cadre des travaux hors tension et des autres documents associés<br />Risques liés à l’utilisation et à la manipulation des matériels et outillages utilisés pour les travaux :<br />&#8211; Identification, vérification et utilisation<br />&#8211; Identification des ouvrages (ou installations) et des zones d’environnement objets des travaux<br />Mesures de prévention à observer lors d’un travail :<br />&#8211; Respect des règles et instructions de sécurité<br />&#8211; Travail hors tension avec ou sans la présence de pièces nues sous tension<br />&#8211; Deuxième étape de consignation<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée<br />Instruction de sécurité spécifique aux essais (pour formation B2V Essai) :<br />&#8211; Respect des règles et instructions de sécurité<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée</p>
<p><span style="font-weight: bolder;">Module « HC – Consignation en haute tension » :</span><br />Documents et informations à échanger ou à transmettre au chargé d’exploitation électrique :<br />&#8211; Rédaction des documents pouvant être utilisés lors d’une consignation (attestation de consignation en une étape, attestation de consignation en deux étapes)<br />&#8211; Identification du chargé d’exploitation et transmission des informations nécessaires<br />&#8211; Identification du chargé de travaux et échange des informations nécessaires<br />Les opérations de consignation :<br />&#8211; Réalisation de la consignation en une étape et de la consignation en deux étapes sur différents types de matériels<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée<br />Analyser les risques et renseigner un avis de réquisition</p>
<p><span style="font-weight: bolder;">Module « HE Manœuvres HTA – Manœuvres en haute tension A » :</span><br /><span style="font-weight: bolder;">Module « HE Manœuvres HTB – Manœuvres en haute tension B » :</span><br /> Identification, vérification et utilisation des équipements de protection individuelle appropriés<br />Limites de l’habilitation « BE Manœuvre » :<br />&#8211; Autorisations et interdictions<br />&#8211; Réalisation des manœuvres dans le domaine de tension concerné<br />Instructions de sécurité spécifiques aux manoeuvres :<br />&#8211; Respect des instructions de sécurité par tout le personnel<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée<br />Documents et informations à échanger ou à transmettre au chargé d’exploitation électrique :<br />&#8211; Identification du chargé d’exploitation et transmission des informations nécessaires<br />&#8211; Respect des instructions données<br />&#8211; Compte-rendu de l’activité<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée</p>
<p><span style="font-weight: bolder;">Module « BE Mesurage BE Vérification – Mesurages et vérifications en haute tension » :</span><br />Rôle du chargé d’exploitation électrique :<br />&#8211; Identification et échange des informations nécessaires<br />&#8211; Respect des instructions données par le chargé d’exploitation électrique<br />&#8211; Compte-rendu de son activité<br />Risques liés à l’utilisation et à la manipulation des matériels et outillages utilisés, spécifiques aux mesurages et/ou aux vérifications (identification, vérification et utilisation du matériel et de l’outillage)<br />Rédaction des documents applicables dans le cadre des mesurages et/ou des vérifications, et autres documents associés (autorisations de travail, instructions de sécurité…)<br />Mesures de prévention à observer lors d’un mesurage et/ou d’une vérification :<br />&#8211; Organisation, délimitation et signalement de la zone de travail<br />&#8211; Respect des procédures de mesurage et/ou de vérification<br />&#8211; Identification des ouvrages ou des installations et des zones d’environnement objets des mesurages et/ou des vérifications<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée</p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="4" role="tab" tabindex="-1" aria-controls="elementor-tab-content-2874" aria-expanded="false">Indicateurs de résultats</div>
					<div id="elementor-tab-content-2874" class="elementor-tab-content elementor-clearfix" data-tab="4" role="tabpanel" aria-labelledby="elementor-tab-title-2874" tabindex="0" hidden="hidden"><div align="center">
<p>Taux de réussite : 100 %</p>
<img decoding="async" class="alignnone size-full wp-image-5904" src="/wp-content/uploads/2024/07/tx_100.png" alt="" width="176" height="141" /></div>
<p>&nbsp;</p>
<div align="center">
<p>La formation est-elle en adéquation avec vos attentes et vos besoins ? 90 %</p>
<img decoding="async" class="aligncenter size-full wp-image-5892" src="/wp-content/uploads/2024/07/ab_90.png" alt="" width="193" height="153" /></div>
<p style="font-size:0.7em">Résultats mis à jour le 25 juin 2024.</p></div>
							</div>
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-0fc2ada elementor-widget elementor-widget-text-editor" data-id="0fc2ada" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p></p>
<p class="wp-block-paragraph"></p>
<p></p>
<p class="wp-block-paragraph"><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);"><u>Délais de réalisation et tarif :</u></span></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);">Inter : selon le <a href="/calendrier/">calendrier</a> semestriel.</span></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);">Intra</span><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align); font-weight: var( --e-global-typography-text-font-weight );"> : devis envoyé sous 4 heures et planification de la session sous 24 heures selon nos disponibilités.</span></p>
<p></p>								</div>
				</div>
				<div class="elementor-element elementor-element-db6352e elementor-widget elementor-widget-post-info" data-id="db6352e" data-element_type="widget" data-e-type="widget" data-widget_type="post-info.default">
				<div class="elementor-widget-container">
							<ul class="elementor-inline-items elementor-icon-list-items elementor-post-info">
								<li class="elementor-icon-list-item elementor-repeater-item-8a6b18c elementor-inline-item">
													<span class="elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-custom">
										Programme mis à jour le 3 juillet 2024					</span>
								</li>
				</ul>
						</div>
				</div>
					</div>
				</div>
				</div>
		<p>L’article <a href="https://www.aspformation.com/electricien-haute-tension-h1-h1v-h2-h2v-hc-essai-he-manoeuvre-mesurage-verification/">Electricien HAUTE Tension : H1- H1V- H2- H2V- HC- Essai – HE Manœuvre- Mesurage- Vérification)</a> est apparu en premier sur <a href="https://www.aspformation.com">ASP Formation</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electricien Basse Tension : Opérations simples (BS- BE Manœuvre- Vérification-Mesurage)</title>
		<link>https://www.aspformation.com/electricien-basse-tension/</link>
		
		<dc:creator><![CDATA[Mathieu]]></dc:creator>
		<pubDate>Thu, 12 Sep 2019 15:08:32 +0000</pubDate>
				<category><![CDATA[Habilitations électriques]]></category>
		<guid isPermaLink="false">http://www.ere-m.com/?p=2260</guid>

					<description><![CDATA[<p>A la fin de la formation, le stagiaire électricien basse tension doit être capable de connaître les dangers de l’électricité et d’analyser le risque électrique, d’intégrer la prévention dans l’organisation du travail, de mettre en œuvre les mesures de prévention et les instructions de l’employeur, et de connaître la conduite à tenir en cas d’accident ou d’incendie d’origine électrique.</p>
<p>L’article <a href="https://www.aspformation.com/electricien-basse-tension/">Electricien Basse Tension : Opérations simples (BS- BE Manœuvre- Vérification-Mesurage)</a> est apparu en premier sur <a href="https://www.aspformation.com">ASP Formation</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="2260" class="elementor elementor-2260" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-5273c204 e-flex e-con-boxed e-con e-parent" data-id="5273c204" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-89928cd elementor-tabs-view-horizontal elementor-widget elementor-widget-tabs" data-id="89928cd" data-element_type="widget" data-e-type="widget" data-widget_type="tabs.default">
				<div class="elementor-widget-container">
							<div class="elementor-tabs">
			<div class="elementor-tabs-wrapper" role="tablist" >
									<div id="elementor-tab-title-1441" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="true" data-tab="1" role="tab" tabindex="0" aria-controls="elementor-tab-content-1441" aria-expanded="false">Public visé</div>
									<div id="elementor-tab-title-1442" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="2" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1442" aria-expanded="false">Moyens pédagogiques</div>
									<div id="elementor-tab-title-1443" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="3" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1443" aria-expanded="false">Détails</div>
									<div id="elementor-tab-title-1444" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="4" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1444" aria-expanded="false">Indicateurs de résultats</div>
							</div>
			<div class="elementor-tabs-content-wrapper" role="tablist" aria-orientation="vertical">
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="true" data-tab="1" role="tab" tabindex="0" aria-controls="elementor-tab-content-1441" aria-expanded="false">Public visé</div>
					<div id="elementor-tab-content-1441" class="elementor-tab-content elementor-clearfix" data-tab="1" role="tabpanel" aria-labelledby="elementor-tab-title-1441" tabindex="0" hidden="false"><p><strong style="color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-size: 1em;">Chargé d’intervention élémentaire (BS)</strong><span style="color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1em;">&nbsp;: Personne assurant des interventions en très basse ou en basse tension. Les interventions sont des opérations électriques simples (uniquement : remplacement de fusible, lampe, accessoired’appareil d’éclairage, prise de courant, interrupteur, raccordement d’un matériel électrique sur un circuit en attente, réarmement d’un dispositif de protection).</span><br></p>
<p></p>
<p><strong>Chargé d’opérations spécifiques (BE Mesurage)</strong>&nbsp;: Personne chargée de diriger ou d’effectuer des mesurages (opérations destinées à mesurer des grandeurs électriques ou des grandeurs physiques) sur des installations électriques.</p>
<p></p>
<p><strong>Chargé d’opérations spécifiques (BE Vérification)</strong>&nbsp;: Personne chargée de diriger ou d’effectuer des vérifications (opérations destinées à s’assurer qu’un ouvrage ou une installation est conforme à un référentiel) sur des installations électriques.</p>
<p></p>
<p><strong>Chargé d’opérations spécifiques (BE Manœuvres d’exploitation)</strong>&nbsp;: Personne chargée de diriger ou d’effectuer des manoeuvres sur des installations électriques (changement de la configuration électrique d’un ouvrage, d’une installation ou de l’alimentation électrique d’un matériel).</p>
<p></p>
<p><strong style="color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-size: 1em;">Accessibilité</strong><span style="color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1em;">&nbsp;:Cette formation est accessible aux personnes en situation de handicap sous certaines conditions (nous consulter)</span><br></p>
<p></p>
<p><strong>Prérequis&nbsp;</strong>:Aptitude médicale. Etre qualifié en électricité pour les opérations visées par ce programme.<br>Etre capable de comprendre les instructions de sécurité</p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="2" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1442" aria-expanded="false">Moyens pédagogiques</div>
					<div id="elementor-tab-content-1442" class="elementor-tab-content elementor-clearfix" data-tab="2" role="tabpanel" aria-labelledby="elementor-tab-title-1442" tabindex="0" hidden="hidden"><p>Formateurs en prévention des risques professionnels, Electriciens de formation<br>Supports d’animation pédagogique standardisés, utilisés en vidéo-projection.</p>
<p></p>
<p><b>Méthode pédagogique&nbsp;:&nbsp;</b>Les enseignements pratiques et les mises en situations d’évaluation des stagiaires représentent 40 % du temps de formation<strong><br></strong></p>
<p><strong>Type d’action</strong>. Formation à la sécurité dépendant de l’article L4141-4 du code du travail Formation en présence physique uniquement (pas de FOAD)Formation en intra-entreprise ou en centre de formation spécialisé.</p>
<p></p>
<p><strong style="color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-size: 1em;">Installations en centre de formation</strong><span style="color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1em;">&nbsp;: salle de cours, tables, chaises, mur clair pour la</span><br></p>
<p>projection, tableau papier ou effaçable. En cas de formation intra-entreprise,<br>des installations équivalentes doivent être mises à disposition par l’employeur<br>des stagiaires.</p>
<p></p>
<p><strong>Moyens techniques</strong><br><strong>Attention :</strong>&nbsp;Lors d’une formation intra-entreprise, s’il est impossible d’organiser la formation pratique dans des conditions représentatives d’un chantier électrique réel, celle-ci pourra être organisée dans un chantier-école. Les appareils utilisés en formation et les équipements de protection individuelle (EPI) doivent être conformes à la réglementation et entretenus. La formation ne pourra avoir lieu si ces obligations réglementaires ne sont pas respectées.</p>
<p></p>
<p><strong>Equipements à mettre à disposition par le client (formation intra) :</strong><br>&#8211; Local électrique<br>&#8211; Armoire à l’intérieur du local contenant des pièces nues sous tension en basse tension<br>&#8211; EPI et équipements de protection (obstacle, nappe, tapis, tabouret, balisage…)<br>&#8211; Outillage et matériels électroportatifs (dont VAT)<br>&#8211; Equipements à mettre hors service (moteur, machine…) pour les opérations de consignation<br>&#8211; Equipements permettant un dépannage et une connexion (pour les interventions)</p>
<p></p>
<p><strong>Moyens d’évaluation</strong>&nbsp;Le formateur évalue les acquis du stagiaire (savoirs et savoir-faire) dans les conditions définies par la NF C 18-510, au moyen d’une fiche standardisée correspondant à une procédure intégrée au système qualité de l’organisme. Une attestation de fin de formation est remise au stagiaire à l’issue de la formation, précisant si les objectifs sont atteints ou non, ou en cours d’acquisition.</p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="3" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1443" aria-expanded="false">Détails</div>
					<div id="elementor-tab-content-1443" class="elementor-tab-content elementor-clearfix" data-tab="3" role="tabpanel" aria-labelledby="elementor-tab-title-1443" tabindex="0" hidden="hidden"><p><span style="font-weight: bolder;">Codes de formation</span><br><span style="font-weight: bolder;">Formacode :</span>&nbsp;24049 – Habilitation électrique NSF : 2553 – Electricité, électronique (non compris automatismes, productique) Textes officiels se rapportant à l’action de formation<br><span style="font-weight: bolder;">Formation certifiante correspondant au Répertoire Spécifique sous les références RS 1633-1635</span><br><span style="font-weight: bolder;">Prévention&nbsp;</span>: Articles L4111-1 à L4154-4 du code du travail. Risque électrique : Articles R4544-1 à R4544-10 du code du travail&nbsp; Opérations électriques : Norme NF C 18-510<br>Formation à la sécurité : Articles L4141-2, R4141-3 et R4141-13 du code du travail</p>
<p></p>
<p><span style="font-weight: bolder;">Durée&nbsp;:&nbsp;</span>14 heures (2 jours)</p>
<p></p>
<p><span style="font-weight: bolder;">Périodicité&nbsp;: &nbsp;</span>Recommandée tous les 3 ans</p>
<p></p>
<p><span style="font-weight: bolder;">Nombre de participants par groupe</span>&nbsp;: 10 personnes maximum</p>
<p></p>
<p><span style="font-weight: bolder;">Moyens d’encadrement&nbsp;:&nbsp;</span>Organisme de formation déclaré à la DIRECCTE</p><p><span style="font-weight: bolder;">Programme détaillé de la formation</span><br><span style="font-weight: bolder;">Module « Tronc commun » :</span><br>Distinction des grandeurs électriques, telles que courant alternatif et continu, intensité, tension, résistance, puissance…<br>Effets du courant électrique sur le corps humain (mécanismes d’électrisation, d’électrocution, de brûlures…)<br>Nom et limites des différents domaines de tension, reconnaissance de l’appartenance des matériels à leur domaine de tension<br>Identification des zones d’environnement et de leurs limites<br>Principe de l’habilitation et définition des symboles d’habilitation (lecture et exploitation du contenu d’un titre d’habilitation)<br>Prescriptions associées aux zones de travail et rôle de chacun des acteurs<br>Principes généraux de prévention à appliquer au cours d’une opération électrique<br>Séquences de la mise en sécurité d’un circuit (consignation, mise hors tension, mise hors de portée) et déroulement des opérations de vérification d’absence de tension<br>Equipements de protection collective et leurs fonctions<br>Equipements de protection individuelle et leurs limites d’utilisation<br>Reconnaissance des zones de travail ainsi que les signalisations associées (équipements de protection collective et leur fonction)<br>Risques liés à l’utilisation et à la manipulation des matériels et outillages utilisés dans l’environnement<br>Conduite à tenir en cas d’accident corporel<br>Procédures, consignes et conduite à tenir en cas d’incendie dans un environnement électrique<br><span style="font-weight: bolder;">Module « BE Manœuvre d’exploitation – Manœuvres en basse tension » :</span><br>Reconnaissance des matériels électriques des domaines de la basse et de la très basse tension dans leur environnement<br>Identification, vérification et utilisation des équipements de protection individuelle appropriés<br>Limites de l’habilitation « BE Manœuvre » :<br>&#8211; Autorisations et interdictions<br>&#8211; Réalisation des manœuvres dans les domaines de la basse et de la très basse tension<br>Documents et informations à échanger ou à transmettre au chargé d’exploitation électrique :<br>&#8211; Identification du chargé d’exploitation et transmission des informations nécessaires<br>&#8211; Respect des instructions données<br>&#8211; Compte-rendu de l’activité<br>Instructions de sécurité spécifiques aux manoeuves de consignation :<br>&#8211; Respect des instructions de sécurité par tout le personnel<br>&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée<br><span style="font-weight: bolder;">Module « BS – Interventions BT élémentaires » :</span><br>Les interventions BT élémentaires et les limites de leur domaine<br>Informations à échanger ou à transmettre au chargé d’exploitation électrique :<br>&#8211; Identification du chargé d’exploitation et transmission des informations nécessaires<br>&#8211; Respect des instructions données<br>&#8211; Compte-rendu de l’activité<br>Fonctions des matériels électriques des domaines de tension BT et TBT<br>Moyens de protection individuelle et leurs limites d’utilisation (identification, vérification et utilisation)<br>Séquences de la mise en sécurité d’un circuit :<br>&#8211; Mise hors tension pour son propre compte<br>&#8211; Vérification d’absence de tension<br>&#8211; Remise sous tension<br>Mesures de prévention à observer lors d’une intervention BT :<br>&#8211; Délimitation et signalement des zones d’intervention BT<br>&#8211; Respect des règles et instructions de sécurité<br>Contenu des documents applicables dans le cadre des interventions &nbsp;BT élémentaires<br>Préparation, organisation et mise en œuvre des mesures de prévention lors d’une intervention BT de remplacement<br>Procédure de raccordement :- Préparation, organisation et mise en œuvre des mesures de prévention lors d’une intervention<br>BT de raccordement hors tension<br>&#8211; Analyse des risques préalablement à chaque situation de travail<br>&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée<br><span style="font-weight: bolder;">Module « BE Mesurage BE Vérification – Mesurages et vérifications en basse tension » :</span><br>Fonctions des matériels électriques en basse et très basse tensions<br>Rôle du chargé d’exploitation électrique :<br>&#8211; Identification et échange des informations nécessaires<br>&#8211; Respect des instructions données par le chargé d’exploitation électrique<br>&#8211; Compte-rendu de son activité<br>Risques liés à l’utilisation et à la manipulation des matériels et outillages utilisés, spécifiques aux mesurages et/ou aux vérifications (identification, vérification et utilisation du matériel et de l’outillage)<br>Rédaction des documents applicables dans le cadre des mesurages et/ou des vérifications, et autres documents associés (autorisations de travail, instructions de sécurité…)<br>Mesures de prévention à observer lors d’un mesurage et/ou d’une vérification :<br>&#8211; Organisation, délimitation et signalement de la zone de travail<br>&#8211; Respect des procédures de mesurage et/ou de vérification<br>&#8211; Identification des ouvrages ou des installations et des zones d’environnement objets des mesurages et/ou des vérifications<br>&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée<br><span style="font-weight: bolder;">Evaluations et bilan de la formation</span><br></p>
<p></p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="4" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1444" aria-expanded="false">Indicateurs de résultats</div>
					<div id="elementor-tab-content-1444" class="elementor-tab-content elementor-clearfix" data-tab="4" role="tabpanel" aria-labelledby="elementor-tab-title-1444" tabindex="0" hidden="hidden"><div align="center">
<p>Taux de réussite : 100 %</p>
<img decoding="async" class="alignnone size-full wp-image-5904" src="/wp-content/uploads/2024/07/tx_100.png" alt="" width="176" height="141" /></div>
<p>&nbsp;</p>
<div align="center">
<p>La formation est-elle en adéquation avec vos attentes et vos besoins ? 90 %</p>
<img decoding="async" class="aligncenter size-full wp-image-5892" src="/wp-content/uploads/2024/07/ab_90.png" alt="" width="193" height="153" /></div>
<p style="font-size:0.7em">Résultats mis à jour le 25 juin 2024.</p></div>
							</div>
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-fd4c58f elementor-widget elementor-widget-text-editor" data-id="fd4c58f" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p></p>
<p class="wp-block-paragraph"></p>
<p></p>
<p class="wp-block-paragraph"><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);"><u>Délais de réalisation et tarif :</u></span></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);">Inter : selon le <a href="/calendrier/">calendrier</a> semestriel.</span></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);">Intra</span><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align); font-weight: var( --e-global-typography-text-font-weight );"> : devis envoyé sous 4 heures et planification de la session sous 24 heures selon nos disponibilités.</span></p>
<p></p>								</div>
				</div>
				<div class="elementor-element elementor-element-16774b3 elementor-widget elementor-widget-post-info" data-id="16774b3" data-element_type="widget" data-e-type="widget" data-widget_type="post-info.default">
				<div class="elementor-widget-container">
							<ul class="elementor-inline-items elementor-icon-list-items elementor-post-info">
								<li class="elementor-icon-list-item elementor-repeater-item-8a6b18c elementor-inline-item">
													<span class="elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-custom">
										Programme mis à jour le 3 juillet 2024					</span>
								</li>
				</ul>
						</div>
				</div>
					</div>
				</div>
				</div>
		<p>L’article <a href="https://www.aspformation.com/electricien-basse-tension/">Electricien Basse Tension : Opérations simples (BS- BE Manœuvre- Vérification-Mesurage)</a> est apparu en premier sur <a href="https://www.aspformation.com">ASP Formation</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electricien Basse Tension : Opérations complexes (B1- B1V- B2- B2V -BR –BC- Essai -Manœuvre de consignation)</title>
		<link>https://www.aspformation.com/electricien-basse-tension-operations-complexes-b1-b1v-b2-b2v-br-bc-essai-manoeuvre-de-consignation/</link>
		
		<dc:creator><![CDATA[Mathieu]]></dc:creator>
		<pubDate>Thu, 12 Sep 2019 15:08:20 +0000</pubDate>
				<category><![CDATA[Habilitations électriques]]></category>
		<guid isPermaLink="false">http://www.ere-m.com/?p=2258</guid>

					<description><![CDATA[<p>A la fin de la formation, le stagiaire doit être capable de connaître les dangers de l’électricité et d’analyser le risque électrique, d’intégrer la prévention dans l’organisation du travail, de mettre en œuvre les mesures de prévention et les instructions de l’employeur, et de connaître la conduite à tenir en cas d’accident ou d’incendie d’origine électrique.</p>
<p>L’article <a href="https://www.aspformation.com/electricien-basse-tension-operations-complexes-b1-b1v-b2-b2v-br-bc-essai-manoeuvre-de-consignation/">Electricien Basse Tension : Opérations complexes (B1- B1V- B2- B2V -BR –BC- Essai -Manœuvre de consignation)</a> est apparu en premier sur <a href="https://www.aspformation.com">ASP Formation</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="2258" class="elementor elementor-2258" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-51c3951a e-flex e-con-boxed e-con e-parent" data-id="51c3951a" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-673e282 elementor-tabs-view-horizontal elementor-widget elementor-widget-tabs" data-id="673e282" data-element_type="widget" data-e-type="widget" data-widget_type="tabs.default">
				<div class="elementor-widget-container">
							<div class="elementor-tabs">
			<div class="elementor-tabs-wrapper" role="tablist" >
									<div id="elementor-tab-title-1081" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="true" data-tab="1" role="tab" tabindex="0" aria-controls="elementor-tab-content-1081" aria-expanded="false">Public visé</div>
									<div id="elementor-tab-title-1082" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="2" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1082" aria-expanded="false">Moyens pédagogiques</div>
									<div id="elementor-tab-title-1083" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="3" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1083" aria-expanded="false">Détails</div>
									<div id="elementor-tab-title-1084" class="elementor-tab-title elementor-tab-desktop-title" aria-selected="false" data-tab="4" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1084" aria-expanded="false">Indicateurs de résultats</div>
							</div>
			<div class="elementor-tabs-content-wrapper" role="tablist" aria-orientation="vertical">
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="true" data-tab="1" role="tab" tabindex="0" aria-controls="elementor-tab-content-1081" aria-expanded="false">Public visé</div>
					<div id="elementor-tab-content-1081" class="elementor-tab-content elementor-clearfix" data-tab="1" role="tabpanel" aria-labelledby="elementor-tab-title-1081" tabindex="0" hidden="false"><p></p>
<p class="wp-block-paragraph"><strong>Exécutant (opérations électriques B1, B1V)</strong> : Personne assurant l’exécution d’opérations électriques sous la conduite d’un chargé de travaux, d’un chargé d’intervention générale ou d’un chargé d’opérations spécifiques.</p>
<p></p>
<p></p>
<p class="wp-block-paragraph"><strong>Chargé de travaux (B2, B2V, B2V Essai)</strong> : Personne assurant la direction effective des travaux électriques ou non, qui doit prendre les mesures nécessaires pour assurer sa sécurité et celle du personnel placé sous sa responsabilité et son autorité</p>
<p></p>
<p></p>
<p class="wp-block-paragraph"><strong>Chargé de consignation (BC) : </strong>Personne chargée d’assurer des consignations électriques<br />(coupure de courant et garantie qu’il ne peut être remis accidentellement).</p>
<p></p>
<p></p>
<p class="wp-block-paragraph"><strong>Chargé d’intervention générale (BR) </strong>: Personne chargée d’assurer des opérations dites<br />générales (maintenance, remise en état de fonctionnement&#8230;) capable de gérer<br />en temps réel l’enchaînement des tâches qu’elle réalise.</p>
<p></p>
<p></p>
<p class="wp-block-paragraph"><strong>Chargé d’opérations spécifiques (BE Manœuvres de consignation)</strong> : Personne chargée de diriger ou d’effectuer des manoeuvres sur des installations électriques (changement de la configuration électrique d’un ouvrage, d’une installation ou de l’alimentation électrique d’un matériel)</p>
<p></p>
<p></p>
<p class="wp-block-paragraph"></p>
<p></p>
<p class="wp-block-paragraph"><strong>Accessibilité</strong> : Cette formation est accessible aux personnes en situation de handicap sous certaines conditions (nous consulter)</p>
<p></p>
<p></p>
<p class="wp-block-paragraph"><strong>Prérequis </strong>Aptitude médicale. Etre qualifié en électricité pour les opérations visées par ce programme.  Etre capable de comprendre les instructions de sécurité</p>
<p></p>
<p></p>
<p class="wp-block-paragraph"></p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="2" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1082" aria-expanded="false">Moyens pédagogiques</div>
					<div id="elementor-tab-content-1082" class="elementor-tab-content elementor-clearfix" data-tab="2" role="tabpanel" aria-labelledby="elementor-tab-title-1082" tabindex="0" hidden="hidden"><p><strong>Méthode pédagogique</strong> Les enseignements pratiques et les mises en situations d’évaluation des stagiaires représentent 40 à 50 % du temps de formation.</p>
<p><strong>Type d’action</strong>. Formation à la sécurité dépendant<br>de l’article L4141-4 du code du travail Formation en présence physique<br>uniquement (pas de FOAD)Formation en intra-entreprise ou en centre de formation spécialisé.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Moyens pédagogiques&nbsp;: </strong>Formateurs en prévention des risques professionnels, Electriciens de formation. Supports d’animation pédagogique standardisés, utilisés en vidéo-projection.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Installations en centre de formation</strong> : salle de cours, tables, chaises, mur clair pour la projection, tableau papier ou effaçable. En cas de formation intra-entreprise, des installations équivalentes doivent être mises à disposition par l’employeur des stagiaires.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Moyens techniques</strong> <strong>Attention :</strong> Lors d’une formation intra-entreprise, s’il est impossible d’organiser la formation pratique dans des conditions représentatives d’un chantier électrique réel, celle-ci pourra être organisée dans un chantier-école.<br>Les appareils utilisés en formation et les équipements de protection individuelle (EPI) doivent être conformes à la réglementation et entretenus. La formation ne pourra avoir lieu si ces obligations réglementaires ne sont pas respectées.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Equipements à mettre à disposition par le client (formation intra) :</strong><br>&#8211; Local électrique<br>&#8211; Armoire à l’intérieur du local contenant des pièces nues sous tension en basse tension<br>&#8211; EPI et équipements de protection (obstacle, nappe, tapis, tabouret, balisage…)<br>&#8211; Outillage et matériels électroportatifs (dont VAT)<br>&#8211; Equipements à mettre hors sevice (moteur, machine…) pour les opérations de consignation<br>&#8211; Equipements permettant un dépannage et une connexion (pour les interventions)</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Moyens d’évaluation</strong> Le formateur évalue les acquis du stagiaire (savoirs et savoir-faire) dans les conditions définies par la NF C 18-510, au moyen d’une fiche standardisée correspondant à une procédure intégrée au système qualité de l’organisme. Une attestation de fin de formation est remise au stagiaire à l’issue de la formation, précisant si les objectifs sont atteints ou non, ou en cours d’acquisition</p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="3" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1083" aria-expanded="false">Détails</div>
					<div id="elementor-tab-content-1083" class="elementor-tab-content elementor-clearfix" data-tab="3" role="tabpanel" aria-labelledby="elementor-tab-title-1083" tabindex="0" hidden="hidden"><p><strong>Codes de formation </strong><br /><strong>Formacode :</strong> 24049 – Habilitation électrique NSF : 2553 – Electricité, électronique (non compris automatismes, productique) Textes officiels se rapportant à l’action de formation<br /><strong>Formation certifiante correspondant au Répertoire Spécifique sous les références RS 1627-1629-1630-1632-1652-1663-1667 </strong></p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Prévention </strong>: Articles L4111-1 à L4154-4 du code du travail. Risque électrique : Articles R4544-1 à R4544-10 du code du travail  Opérations électriques : Norme NF C 18-510 <br />Formation à la sécurité : Articles L4141-2, R4141-3 et R4141-13 du code du travail</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Durée : </strong>21 heures (3 jours)</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Périodicité :  </strong>Recommandée tous les 3 ans</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Nombre de participants par groupe</strong> : 10 personnes maximum</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><strong>Moyens d’encadrement : </strong>Organisme de formation déclaré à la DIRECCTE</p>
<p><strong>Programme détaillé de la formation</strong></p>
<p><strong>Module « Tronc commun » :</strong><br />Distinction des grandeurs électriques, telles que courant alternatif et continu, intensité, tension, résistance, puissance…<br />Effets du courant électrique sur le corps humain (mécanismes d’électrisation, d’électrocution, de brûlures…)<br />Nom et limites des différents domaines de tension, reconnaissance de l’appartenance des matériels à leur domaine de tension<br />Identification des zones d’environnement et de leurs limites<br />Principe de l’habilitation et définition des symboles d’habilitation (lecture et exploitation du contenu d’un titre d’habilitation)<br />Prescriptions associées aux zones de travail et rôle de chacun des acteurs<br />Principes généraux de prévention à appliquer au cours d’une opération électrique<br />Séquences de la mise en sécurité d’un circuit (consignation, mise hors tension, mise hors de portée) et déroulement des opérations de vérification d’absence de tension<br />Equipements de protection collective et leurs fonctions<br />Equipements de protection individuelle et leurs limites d’utilisation<br />Reconnaissance des zones de travail ainsi que les signalisations associées (équipements de protection collective et leur fonction)<br />Risques liés à l’utilisation et à la manipulation des matériels et outillages utilisés dans l’environnement<br />Conduite à tenir en cas d’accident corporel<br />Procédures, consignes et conduite à tenir en cas d’incendie dans un environnement électrique</p>
<p><strong>Module « BE Manœuvre de consignation – Manœuvres en basse tension » :</strong><br />Reconnaissance des matériels électriques des domaines de la basse et de la très basse tensions dans leur environnement<br />Identification, vérification et utilisation des équipements de protection individuelle appropriés<br />Limites de l’habilitation « BE Manœuvre » :<br />&#8211; Autorisations et interdictions<br />&#8211; Réalisation des manœuvres dans les domaines de la basse et de la très basse tensions<br />Documents et informations à échanger ou à transmettre au chargé d’exploitation électrique :<br />&#8211; Identification du chargé d’exploitation et transmission des informations nécessaires<br />&#8211; Respect des instructions données<br />&#8211; Compte-rendu de l’activité<br />Instructions de sécurité spécifiques aux manœuvres de consignation :<br />&#8211; Respect des instructions de sécurité par tout le personnel<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée</p>
<p><strong>Module « BR – Interventions BT générales » :</strong></p>
<p>Les interventions BT (générales et élémentaires) et les limites de leur domaine<br />Fonction des matériels électriques en basse et très basse tensions<br />Documents et informations à échanger ou à transmettre au chargé d’exploitation électrique :<br />&#8211; Identification du chargé d’exploitation et transmission des informations nécessaires<br />&#8211; Respect des instructions données<br />&#8211; Compte-rendu de l’activité<br />Rédaction des documents applicables dans le cadre des interventions BT (autorisation d’accès, instruction de sécurité…)<br />Mesures de prévention à observer lors d’une intervention BT :<br />&#8211; Organisation, délimitation et signalement des zones d’intervention BT<br />&#8211; Elimination du risque de présence de tension dans la zone de voisinage renforcé BT<br />&#8211; Respect des procédures d’intervention BT par tout le personnel pour une réalisation en sécurité<br />Opérations de consignation et documents associés :<br />&#8211; Réalisation des opérations de consignation<br />&#8211; Identification des zones d’environnement dans lesquelles il peut intervenir<br />&#8211; Réalisation d’une opération de dépannage ; réalisation d’une opération de mesurage et d’essai<br />&#8211; Réalisation des opérations de connexion et déconnexion en présence ou non de tension<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée</p>
<p> </p>
<p> </p>
<p><strong>Module « BC – Consignation en basse tension » :</strong><br />Fonctions des matériels électriques en basse et très basse tensions<br />Documents et informations à échanger ou à transmettre au chargé d’exploitation électrique :<br />&#8211; Rédaction des documents pouvant être utilisés lors d’une consignation (attestation de consignation en une étape, attestation de consignation en deux étapes)<br />&#8211; Identification du chargé d’exploitation et transmission des informations nécessaires<br />&#8211; Identification du chargé de travaux et échange des informations nécessaires<br />Les opérations de consignation :<br />&#8211; Réalisation de la consignation en une étape et de la consignation en deux étapes sur différents types de matériels<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée</p>
<p> </p>
<p> </p>
<p><strong>Module « B1 B2 B1V B2V B2V Essai – Exécutant et Chargé de travaux hors tension » :</strong><br />Travaux hors tension avec ou sans environnement électrique<br />Rôles du chargé de consignation et du chargé d’exploitation électrique :<br />&#8211; Respect des instruction données par le chargé de travaux (exécutant)<br />&#8211; Identification du chargé d’exploitation et échange des informations nécessaires (chargé de travaux)<br />&#8211; Respect des instructions données par le chargé d’exploitation électrique ou par le chargé de consignation (chargé de travaux)<br />&#8211; Compte-rendu de son activité<br />Identification des différents niveaux d’habilitation (et leurs limites) susceptibles d’être rencontrés dans le cadre des travaux hors tension avec ou sans présence de pièces nues sous tension<br />Prescriptions d’exécution des travaux :<br />&#8211; Organisation, délimitation et signalement des zones de travail<br />&#8211; Elimination du risque de présence de tension dans la zone de voisinage renforcé BT<br />&#8211; Respect des zones de travail<br />Fonctions des matériels électriques en basse et très basse tensions<br />Rédaction et vérification des documents applicables dans le cadre des travaux hors tension et des autres documents associés<br />Risques liés à l’utilisation et à la manipulation des matériels et outillages utilisés pour les travaux :<br />&#8211; Identification, vérification et utilisation<br />&#8211; Identification des ouvrages (ou installations) et des zones d’environnement objets des travaux<br />Mesures de prévention à observer lors d’un travail :<br />&#8211; Respect des règles et instructions de sécurité<br />&#8211; Travail hors tension avec ou sans la présence de pièces nues sous tension<br />&#8211; Deuxième étape de consignation<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée<br />Instruction de sécurité spécifique aux essais (pour formation B2V Essai) :<br />&#8211; Respect des règles et instructions de sécurité<br />&#8211; Analyse des risques pour une situation donnée et correspondant à l’habilitation visée<br /><strong>Evaluations et bilan de la formation</strong></p></div>
									<div class="elementor-tab-title elementor-tab-mobile-title" aria-selected="false" data-tab="4" role="tab" tabindex="-1" aria-controls="elementor-tab-content-1084" aria-expanded="false">Indicateurs de résultats</div>
					<div id="elementor-tab-content-1084" class="elementor-tab-content elementor-clearfix" data-tab="4" role="tabpanel" aria-labelledby="elementor-tab-title-1084" tabindex="0" hidden="hidden"><div align="center">
<p>Taux de réussite : 100 %</p>
<img decoding="async" class="alignnone size-full wp-image-5904" src="/wp-content/uploads/2024/07/tx_100.png" alt="" width="176" height="141" /></div>
<p>&nbsp;</p>
<div align="center">
<p>La formation est-elle en adéquation avec vos attentes et vos besoins ? 90 %</p>
<img decoding="async" class="aligncenter size-full wp-image-5892" src="/wp-content/uploads/2024/07/ab_90.png" alt="" width="193" height="153" /></div>
<p style="font-size:0.7em">Résultats mis à jour le 25 juin 2024.</p></div>
							</div>
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-bbbc44b elementor-widget elementor-widget-text-editor" data-id="bbbc44b" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><!-- wp:paragraph --></p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);"><u>Délais de réalisation et tarif :</u></span></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);">Inter : selon le <a href="/calendrier/">calendrier</a> semestriel.</span></p>
<p><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align);">Intra</span><span style="color: #000000; font-family: Poppins; font-size: 1.3rem; text-align: var(--text-align); font-weight: var( --e-global-typography-text-font-weight );"> : devis envoyé sous 4 heures et planification de la session sous 24 heures selon nos disponibilités.</span></p>
<p><!-- /wp:paragraph --></p>								</div>
				</div>
				<div class="elementor-element elementor-element-d523a2a elementor-widget elementor-widget-post-info" data-id="d523a2a" data-element_type="widget" data-e-type="widget" data-widget_type="post-info.default">
				<div class="elementor-widget-container">
							<ul class="elementor-inline-items elementor-icon-list-items elementor-post-info">
								<li class="elementor-icon-list-item elementor-repeater-item-8a6b18c elementor-inline-item">
													<span class="elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-custom">
										Programme mis à jour le 3 juillet 2024					</span>
								</li>
				</ul>
						</div>
				</div>
					</div>
				</div>
				</div>
		<p>L’article <a href="https://www.aspformation.com/electricien-basse-tension-operations-complexes-b1-b1v-b2-b2v-br-bc-essai-manoeuvre-de-consignation/">Electricien Basse Tension : Opérations complexes (B1- B1V- B2- B2V -BR –BC- Essai -Manœuvre de consignation)</a> est apparu en premier sur <a href="https://www.aspformation.com">ASP Formation</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
